design with ball bearing guarantees long service life. 3 Electrical connection via 2-pole terminal strip. 4 All tests were performed according to European Norms; EN 60068-2-6 | 60068-2-27 | 60068-2-29 Railway [...] and for use in the telecommunications sector. all tests were conducted according to European Norms, EN 60068-2-6 / 60068-2-27 / 60068-2-29 Railway applications – Rolling stock equipment – Shock and vibration [...] be used under extreme conditions (–40 °C … +70 °C) fan design with ball bearing: guaranteed long service life voltage range: 230 V / 115 V / 50/60 Hz DIN rail mounting extreme T conditions integrated thermostat
fleece filter mat. Pfannenberg G4 fleece fibre mats have the highest filter class according to DIN EN 779 and are the perfect filter medium for the majority of applications. They guarantee reliable air [...] and water jets. Compared to standard synthetic fibre filter mats, they allow up to a 300 % longer service life, saving time and money on maintenance. Suitable for: size size size size The best protection: [...] • • • Dust • • • Wood chips • • • Paint fumes • • Air conditioning • • Cement particles • Longer service life (up to 300 %) • Protection against water jets • See all filter mats
enclosure due to long passage of air, therefore hot spots are eliminated • Exceptional serviceability • Service port for easy retrieval of parameter settings/history (Pfannenberg εCOOL-Plant software [...] changing service friendly UL listed for Canada and US EurAsian Conformity Data DTI 6401 DTS 6401 Rated voltage ¹ ±10 % AC 50/60 Hz 400 V 3~ 230 V 400 V 3~ 230 V Cooling capacity according to EN 14511 A35/A35 [...] A35/A50 1500 W Ambient temperature +10 … +55 °C / +50 … +131 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosureif used as intended by the manufacturer Condensate management
enclosure due to long passage of air, therefore hot spots are eliminated • Exceptional serviceability • Service port for easy retrieval of parameter settings/history (Pfannenberg εCOOL-Plant software [...] changing service friendly UL listed for Canada and US EurAsian Conformity Data DTI 6201 DTS 6201 Rated voltage ¹ ±10 % AC 50/60 Hz 400 V 2~ 230 V 400 V 2~ 230 V Cooling capacity according to EN 14511 A35/A35 [...] W A35/A50 750 W Ambient temperature +10 … +55 °C / +50 … +131 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosure if used as intended by the manufacturer Condensate management
enclosure due to long passage of air, therefore hot spots are eliminated • Exceptional serviceability • Service port for easy retrieval of parameter settings/history (Pfannenberg εCOOL-Plant software [...] changing service friendly UL listed for Canada and US EurAsian Conformity Data DTI 6301 DTS 6301 Rated voltage ¹ ±10 % AC 50/60 Hz 400 V 2~ 230 V 400 V 2~ 230 V Cooling capacity according to EN 14511 A35/A35 [...] A35/A50 1200 W Ambient temperature +10 … +55 °C / +50 … +131 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosure if used as intended by the manufacturer Condensate management
enclosure due to long passage of air, therefore hot spots are eliminated • Exceptional serviceability • Service port for easy retrieval of parameter settings/history (Pfannenberg εCOOL-Plant software [...] filter mat changing service friendly UL listed for Canada and US EurAsian Conformity Data DTI 6501 DTS 6501 Rated voltage ¹ ±10 % AC 50/60 Hz 400 V 3~ Cooling capacity according to EN 14511 A35/A35 2500 [...] A35/A50 1800 W Ambient temperature +10 … +55 °C / +50 … +131 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosureif used as intended by the manufacturer Condensate management
enclosure due to long passage of air, therefore hot spots are eliminated • Exceptional serviceability • Service port for easy retrieval of parameter settings/history (Pfannenberg εCOOL-Plant software [...] filter mat changing service friendly UL listed for Canada and US EurAsian Conformity Data DTI 6801 DTS 6801 Rated voltage ¹ ±10 % AC 50/60 Hz 400 V 3~ Cooling capacity according to EN 14511 A35/A35 4000 [...] A35/A50 3150 W Ambient temperature +10 … +55 °C / +50 … +131 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosureif used as intended by the manufacturer Condensate management
thanks to ideal, patented condensate management system service-friendly: toolless mounting and maintenance thanks to quick installation frame service-friendly: complete cover removable towards the front [...] mounting tool-less filter mat changing service friendly Data DTT 6201 Rated voltage ±10 % AC 50/60 Hz AC 60 Hz 400 V 2~¹ 230 V 115 V Cooling performance according to EN 14511 A35/A35 1000 / 1080 W A35/A50 [...] A35/A50 600 / 640 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure if used as intended by the manufacturer IP 34 towards the
thanks to ideal, patented condensate management system service-friendly: toolless mounting and maintenance thanks to quick installation frame service-friendly: complete cover removable towards the front [...] mounting tool-less filter mat changing service friendly Data DTT 6301 Rated voltage ±10 % AC 50/60 Hz AC 60 Hz 400 V 2~¹ 230 V 115 V Cooling performance according to EN 14511 A35/A35 1500 / 1620 W A35/A50 [...] A35/A50 1000 / 1160 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure if used as intended by the manufacturer IP 34 towards
thanks to ideal, patented condensate management system service-friendly: toolless mounting and maintenance thanks to quick installation frame service-friendly: complete cover removable towards the front [...] tool-less mounting tool-less filter mat changing service friendly Data DTT 6401 Rated voltage ±10 % AC 50/60 Hz 400/460 V 3~¹ 230 V Cooling performance according to EN 14511 A35/A35 2000 / 2100 W A35/A50 1540 [...] 1540 / 1600 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure if used as intended by the manufacturer IP 34 towards the