+34 … +158 °F Water outlet temperature +1 … +35 °C / +34 … +95 °F Degrees of protection according to EN 60529 IP 55 towards the electrical enclosure if used as intended by the manufacturer Further technical [...] product integration into your planning and documentation (such as Eplan macros) can be found at MyPfannenberg . Ordering details PWD 5402 PWD 5302 Rated voltage 230 V AC Article number 12065410055 12065310055 [...] heat load will not be transferred to the ambient air. Integrated temperature monitoring with alarm contact. 2 Surface seal to protect against the penetration of water via the roof surface of the control cabinet
V 3~ Cooling performance according to EN 14511 A35/A35 2000 W A35/A50 1440 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure [...] enclosure due to long passage of air, therefore hot spots are eliminated. Integrated fault and door contact. DTS variant: cut-out compatible with PWS 7332 L air/water heat exchanger. partially recessed mounting [...] product integration into your planning and documentation (such as Eplan macros) can be found at MyPfannenberg . Ordering details DTI 9441 Type Rated voltage 400/460 V AC Standard Controller Article number
230 V Cooling performance according to EN 14511 A35/A35 1000 W A35/A50 780 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure [...] enclosure due to long passage of air, therefore hot spots are eliminated. Integrated fault and door contact. Optionally available with integrated condensate evaporation system. partially recessed mounting [...] product integration into your planning and documentation (such as Eplan macros) can be found at MyPfannenberg . Ordering details DTI 9241 Type Rated voltage 400 V AC 230 V AC Standard Controller Article number
230 V Cooling performance according to EN 14511 A35/A35 1500 W A35/A50 1200 W Ambient temperature +15 … +55 °C / +59 … +131 °F Degrees of protection according to EN 60529 IP 54 towards the electrical enclosure [...] enclosure due to long passage of air, therefore hot spots are eliminated. Integrated fault and door contact. Optionally available with integrated condensate evaporation system. DTS variants: cut-out compatible [...] product integration into your planning and documentation (such as Eplan macros) can be found at MyPfannenberg . Ordering details DTI 9341 Type Rated voltage 400 V AC 230 V AC Standard Controller Article number